Part Number Hot Search : 
AD5667R MA158TSK MOC70T3 AD5667R AD5667R 2SC3502C SF2060B MC33072
Product Description
Full Text Search
 

To Download A905 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  dual channel, 20mhz oscilloscope with true rms dmm. technicians appreciate the bright backlight of the 3" x 3" cold cathode flourescent display and rugged construction inside and out. new with the 460 ? cursor readout  decibels  pre and post triggering  culus 3111 460 handheld oscilloscope your tools at work the value leader ? optional accessories protective boot a403 protect against impact and wear. hanging boot hook a103 work hands free with the 440?s protective boot and hook. pc software & rs232 cable a402 download data and waveforms from the 460 to any pc using microsoft windows. soft zipper case a900 keep your 440, ac/dc charger, test leads and optional accessories at the ready. moveable partitions and adjust- able shoulder strap. clamp-on adapters a251 measure up to 400 ac amps. a256 measure up to 400 ac/dc amps. a296 measure up to 2,000 ac/dc amps. low current adapter a254 measures from 10ma to 60 amps ac/dc. current shunt adapter a130 allows any dmm with ac/dc millivolt range to measure up to 30 amps. temperature adapter a301 measure -40o to 500o f. for k-type thermocouple probes. fused test leads ftlk1 reduce your risk of electrical shocks and/or instrument damage. high voltage probe hv40c measure up to 40 kv dc. test lead kits w/silicone insulation tls2000b shuttered plug tls2000rb right angle plug pressure adapter a620 measure up to 500 psi. a630 measure up to 10,000 psi. cigarette lighter dc adapter a408 charge the 440 while on the road or in remote locations. power quality variable speed drives industrial motor controls battery testing programmable logic controls nc/cnc machines uninterruptable power supplies audio video industrial lighting controls factory automation line conditioners voltage regulators inverters gaming industry tpi 460 applications see page two for technical information. to learn about the entire tpi product line visit www.tpi-thevalueleader.com tpi offers a complete line of? handheld oscilloscopes digital multimeters digital clamp-on meters gas detection instruments combustion analyzers refrigeration leak detectors digital manometers contact and infrared temperature instruments oscilloscope probes surface mount test clips bnc-bnc molded coax cables f-series cables full line of accessories test products international, inc. headquarters: 9615 sw allen blvd. beaverton, or 97005 usa 503-520-9197 fax: 503-520-1225 e-mail: info@tpi-thevalueleader.com test products international, ltd. 342 bronte st. south unit #9 milton, ontario l9t 5b7 canada 905-693-8558 fax: 905-693-0888 e-mail: info@tpicanada.com test products international uk, ltd. longley house, east park crawley, west sussex rh10 6ap england +44 (0)1293 561212 fax: +44 (0) 1293 813465 e-mail: info@tpi-uk.com l taw 460 0704 copyright ? 2004 test products international, inc. all pricing subject to changes without notice. distributed by: a403 a103 tls200orb 460 features 20 mhz bandwidth capture signals from ac/dc drive motors, sensors, actuators, line and control voltages, ups and industrial machines. cursor readout measure the width and amplitude of the signal and display it on the screen instead of trying to figure it out manually. decibels accurately measure sound signals. pre and post triggering view the waveform before and after the point the scope triggers at to find glitches and other anomalies with the signal. trend mode graph readings over a predetermined time period to check for surges or dropouts. dual input view two waveforms on the display for comparison and troubleshooting. true rms dmm measure ac/dc volts up to 600v, frequency to 20 mhz, and resistance to 20 meg ohm. obtain accurate measurements of non-sinusoidal ac voltage and current waveforms found in controls and circuits with true rms. screen size backlight lcd bandwidth cursor readout resolution true rms charger banana to bnc adapters (2) dc-60 mhz x1x10 probe 76mm x 76mm (3? x 3?) 72mm x 72mm (2.8? x 2.8?) cold cathode flourescent cold cathode flourescent 20mhz 20mhz 8 bit 8 bit yes yes yes yes yes no yes yes compare tpi 460 fluke 123 included two test leads, two banana to bnc adapters, one dc-60 mhz x 1 x 10 passive oscilloscope probe, power supply and instruction manual real time sample rate capture spikes and dropouts of industrial signals with real time sampling of 25 megasamples per second. bright lcd backlight adjust brightness levels for clarity in any light condition. optically isolated rs232 output transfer data safely without a direct connection to your computer?s circuitry. continuous autoset feature automatically determines the correct vertical and horizontal settings for optimum waveform viewing. autoset provides hands free operation while moving between test points. test products intl.  www.tpi-thevalueleader.com the above information is provided to the best of tpi?s knowledge and is not guaranteed. the above information is subject to change at any time. yes no
faq dual channel, 20mhz oscilloscope with true rms dmm specifications and frequently asked questions included two test leads, two banana to bnc adapters, one dc-60 mhz x1 x10 passive oscilloscope probe, power supply and instruction manual industrial motor control view start-up in rush currents, waveform symmetry, scr trigger pulses, variable frequency drive signals, pulse width modulation, noise, misc. ac/dc speed control signals. power quality noise on industrial feeds, ac voltage waveshape, current wave- forms, machine start-up/power quality interference and noise. programmable logic controls plc input and output signals, control signals, signal conditioning circuits, communications lines and power supplies. nc machines power quality, sensor outputs, control circuits, safety circuits, calibration and adjustments. uninterruptable power supplies sensing and monitoring circuits, switching circuits, output waveforms and current waveforms. audio public address feeds, amplifiers, mixers and preamps. video horizontal and vertical scan rates, z-axis blanking, sync pulses and luminance. industrial lighting controls scr and other solid state designs. factory automation robot control signals, machine vision, machine control and sensing circuits, calibration of positioning systems, analog controllers and servo controls. line conditioners noise and quality. voltage regulators noise and stability. inverters waveform quality. applications certification of calibration, certificate of compliance for details and related fees, call 800-368-5719. pressure adapter a620 measure up to 500 psi. temperature adapter a301 measure -40 to 500 f. for k-type thermo- couple probes, refer to pages 18-19. clamp-on adapters a251 measure up to 400 ac amps. clamp-on adapter a256 measure up to 400 ac/dc amps. clamp-on adapter a296 measure up to 2,000 ac/dc amps. pc software & rs232 cable a404 download data and waveforms from the 460 to any pc using microsoft ? windows ? . surface mount test clips multicolored clips to access 0.3 pitch leads. see page 26. high voltage probe hv15hfa measure accurately up to 15kv dc. see page 11. low current adapter a254 measure below one amp ac/dc. current shunt adapter a130 extend amp range to 30 amps. protective boot a405 guard against inevitable impacts. unique rear cut-out design allows deploy- ment of 460?s rear tilt stand. soft zipper case A905 protect and organize your 460. optional accessories vertical bandwidth 20 mhz w/sp60b 10:1 probe 10 mhz w/shielded test leads sample rate real time 25 megasamples per second up to 2 mhz equivalent time 500 megasamples per second > 2 mhz sensitivity 50mv to 200v/div 1,2,5 sequence coupling ac, dc, gnd resolution 8 bits accuracy (3% + 0.05 range/div) horizontal modes single, normal, auto samples per division 25 accuracy equivalent time: (0.5% + 0.08 time/div) real time: (0.1% + 0.04 time/div) trigger source internal modes free run, normal sensitivity equivalent time: 3 divisions or more real time: 2 divisions or more trend mode plot time 30 sec/div to 1 hour/div plot data type max/min selectable memory 2 screens true rms dmm dcv (ch1, ch2) 400mv, 4, 40, 400, 600v basic accuracy: (0.5% + 5 digits) acv (ch1, ch2) 400mv, 4, 40, 400, 600v basic accuracy: (1% + 10 digits) frequency (ch1, ch2) 1 hz to 20 mhz basic accuracy: (0.5% + 5 digits) ohm (ch1 only) 400, 4k, 40k, 400k, 4m, 20m basic accuracy: (0.5% + 5 digits) continuity (ch1 only) sounds < 0.1k ohm, (2% + 5 digits) specifications why do you need a 20 mhz oscilloscope? to measure signals and voltage anomalies, and to look for glitches that may damage or even shut down electronic machinery. view sine waves on power supplies, motors, and bead board circuitry. pinpoint certain glitches on the sine wave to zero in on the problem and monitor changing patterns or distortion in electrical currents. what are the different waveform patterns displayed on your handheld oscilloscopes? an ac waveform known as sine wave displays voltage against time in the shape of a sine curve. the saw tooth waveform displays a ramped angle and a sharp downward return to its earlier value. (its display pattern resembles the cutting edge of a saw.) a square waveform graphically plots a series of vertical square shapes repeated with spacing between peaks. why is it important to have trend mode? trend mode is great for monitoring sudden intermittents caused by loose connections, dirt, or damaged wires. by setting the minimum and maximum parameters, you can monitor, even record the changes. what is the purpose of triggering? simply zoom in on certain parts of the sine wave and ?hold? to measure and monitor that particular part you are reading. a must have when searching for glitches and distortion on all measurements. international version: 220v 50/60hz ac/dc adapter is included when specifying model no. 460x. optional accessories 60 mhz oscilloscope probe three monolithic inter- changeable probes in 60, 100, and 250 mhz band- width. see page 25. technicians appreciate the bright backlight of the 3" x 3" cold cathode flourescent display and rugged construction inside and out. cursor readout culus 20 mhz bandwidth capture signals from ac/dc drive motors, sensors, actuators, line and control voltages, ups and industrial machines. cursor readout allows you to measure the width and amplitude of the signal and display it on the screen instead of trying to figure it out manually. decibels allows you to accurately measure sound signals. pre and post triggering view the waveform before and after the point the scope triggers at to find glitches and other anomalies with the signal. trend mode graph readings over a predetermined time period to check for surges or dropouts. dual input view two waveforms on the display for comparison and trou- bleshooting. true rms dmm measure ac/dc volts up to 600v, frequency to 20 mhz, and resistance to 20 meg ohm. true rms allows you to obtain accurate measurements of non-sinusoidal ac voltage and cur- rent waveforms found in controls and circuits. real time sample rate capture spikes and dropouts of industrial signals with real time sampling of 25 megasamples per second. bright lcd backlight adjust brightness levels for clarity under any light condition. optically isolated rs232 output transfer data safely without a direct connection to your computer?s circuitry. continuous autoset feature automatically determines the correct vertical and horizontal settings for optimum waveform viewing. autoset provides hands free operation while moving between test points. features


▲Up To Search▲   

 
Price & Availability of A905

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X